Introduction of GENT water to air heat pump  1. What is water to air heat pump? GENT water to air heat pump is a high efficiency Air Conditioning unit that uses natural water at normal temperature as the cooling and heating source and the refrigerant as the medium to achieve indoor space heating and cooling by blowing air directly into the room.  2. What is the available water source for the unit? The water to air ac unit uses natural water at normal temperature as the heating and cooling source, such as surface runoff, groundwater, etc. During the operation of the unit, the water pump draws water from the preset water intake point, and then the water enters the unit to exchange heat with the indoor air. After the heat exchange, the water will be discharged back to the water intake point through the water pump.  3. What is the working principle of the unit? The water cooled ac unit uses the natural water at normal temperature as the heating and cooling source and refrigerant as the medium to achieve the direct heat exchange between the cooling and heating source and indoor air. In winter, the unit transports the heat in the water source to the room to achieve indoor space heating, and in summer, the unit discharges the heat in the indoor air into the water to achieve indoor space cooling.  4. What is the output of the unit? The water cooled air con directly produces air, and achieves indoor space heating and cooling by blowing air directly into the room. Therefore, the direct expansion unit does not need matching terminals, which can effectively control the equipment purchase cost and the installation difficulty.  5. What are the significant features of the unit? Stable operation and significant cooling and heating effect As the heating and cooling source of the water cooled air conditioner, the natural water at normal temperature has a stable temperature all year round, so it can ensure the stable operation of the unit. In addition, the water temperature will not be too high in summer and too low in winter, so the unit can still have excellent cooling and heating effects when the ambient temperature is extremely high or extremely low. What’s more, during the operation of the unit, the cooling and heating source directly exchange heat with the indoor air without a secondary heat exchange process, so the unit has a significant cooling and heating effect.  In summary, this is a unit that is very worthy of users’ consideration. Users who are interested in this water cooled air conditioning units or have indoor cooling and heating needs are welcome to communicate with us.   water cooled ac unit,water to air ac unit,water cooled air con,water cooled air conditioner,water cooled air conditioning units GUANGZHOU GENT NEW ENERGY TECHNOLOGY CO., LTD , https://www.gentgz.com
Type
Head (m)
Flow (m³/h)
Power (KW)
Speed (r/min)
CDL1-2
11.5
1
0.37
2900
CDL1-3
17
1
0.37
2900
CDL1-4
22.5
1
0.37
2900
CDL1-5
28
1
0.37
2900
CDL1-6
33.5
1
0.37
2900
CDL1-7
39
1
0.37
2900
CDL1-8
45
1
0.55
2900
CDL1-9
51
1
0.55
2900
CDL1-10
57
1
0.55
2900
CDL1-17
95
1
1.1
2900
CDL1-19
106
1
1.1
2900
CDL1-21
117
1
1.1
2900
CDL1-23
128
1
1.1
2900
CDL1-25
139
1
1.5
2900
CDL1-27
150
1
1.5
2900
CDL1-30
166
1
1.5
2900
CDL1-33
183
1
2.2
2900
CDL1-36
200
1
2.2
2900
CDL2-2
15
2
0.37
2900
CDL2-3
22
2
0.37
2900
CDL2-4
30
2
0.55
2900
CDL2-5
37
2
0.55
2900
CDL2-6
45
2
0.75
2900
CDL2-7
52
2
0.75
2900
CDL2-9
67
2
1.1
2900
CDL2-11
82
2
1.1
2900
CDL2-13
98
2
1.5
2900
CDL2-15
112
2
1.5
2900
CDL2-18
136
2
2.2
2900
CDL2-22
165
2
2.2
2900
CDL2-26
198
2
3.0
2900
CDL3-2
9
3
0.37
2900
CDL3-3
14
3
0.37
2900
CDL3-4
19
3
0.37
2900
CDL3-5
23
3
0.37
2900
CDL3-6
28
3
0.55
2900
CDL3-7
32
3
0.55
2900
CDL3-8
37
3
0.75
2900
CDL3-9
42
3
0.75
2900
CDL3-10
47
3
0.75
2900
CDL3-11
51
3
1.1
2900
CDL3-12
55
3
1.1
2900
CDL3-13
60
3
1.1
2900
CDL3-15
69
3
1.1
2900
CDL3-17
79
3
1.5
2900
CDL3-19
88
3
1.5
2900
CDL3-21
98
3
2.2
2900
CDL3-23
107
3
2.2
2900
CDL3-25
116
3
2.2
2900
CDL3-27
124
3
2.2
2900
CDL3-29
133
3
2.2
2900
CDL3-31
142
3
3
2900
CDL3-33
151
3
3
2900
CDL3-36
168
3
3
2900
CDL4-2
15
4
0.37
2900
CDL4-3
24
4
0.55
2900
CDL4-4
32
4
0.75
2900
CDL4-5
40
4
1.1
2900
CDL4-6
48
4
1.1
2900
CDL4-7
56
4
1.5
2900
CDL4-8
64
4
1.5
2900
CDL4-10
81
4
2.2
2900
CDL4-12
95
4
2.2
2900
CDL4-14
112
4
3
2900
CDL4-16
129
4
3
2900
CDL4-19
153
4
4
2900
CDL4-22
178
4
4
2900
CDL8-2/1
9
8
0.75
2900
CDL8-2
18
8
0.75
2900
CDL8-3
27
8
1.1
2900
CDL8-4
36
8
1.5
2900
CDL8-5
45
8
2.2
2900
CDL8-6
54
8
2.2
2900
CDL8-8
73
8
3.0
2900
CDL8-10
92
8
4.0
2900
CDL8-12
111
8
4.0
2900
CDL8-14
130
8
5.5
2900
CDL8-16
148
8
5.5
2900
CDL8-18
167
8
7.5
2900
CDL8-20
186
8
7.5
2900
CDL12-2
20
12
1.5
2900
CDL12-3
30
12
2.2
2900
CDL12-4
40
12
3
2900
CDL12-5
50
12
3
2900
CDL12-6
60
12
4
2900
CDL12-7
70
12
5.5
2900
CDL12-8
80
12
5.5
2900
CDL12-9
91
12
5.5
2900
CDL12-10
101
12
7.5
2900
CDL12-12
121
12
7.5
2900
CDL12-14
141
12
11
2900
CDL12-16
162
12
11
2900
CDL12-18
183
12
11
2900
CDL16-2
22
16
2.2
2900
CDL16-3
34
16
3.0
2900
CDL16-4
46
16
4.0
2900
CDL16-5
58
16
5.5
2900
CDL16-6
70
16
5.5
2900
CDL16-7
82
16
7.5
2900
CDL16-8
94
16
7.5
2900
CDL16-10
118
16
11
2900
CDL16-12
141
16
11
2900
CDL16-14
166
16
15
2900
CDL16-16
189
16
15
2900
CDL20-1
10
20
1.1
2900
CDL20-2
23
20
2.2
2900
CDL20-3
35
20
4.0
2900
CDL20-4
47
20
5.5
2900
CDL20-5
58
20
5.5
2900
CDL20-6
70
20
7.5
2900
CDL20-7
82
20
7.5
2900
CDL20-8
94
20
11
2900
CDL20-10
118
20
11
2900
CDL20-12
142
20
15
2900
CDL20-14
166
20
15
2900
CDL20-17
202
20
18.5
2900
CDL32-10-1
9
32
1.5
2900
CDL32-10
13
32
2.2
2900
CDL32-20-2
20
32
3.0
2900
CDL32-20
27
32
4.0
2900
CDL32-30-2
33
32
5.5
2900
CDL32-30
40
32
5.5
2900
CDL32-40-2
46
32
7.5
2900
CDL32-40
53
32
7.5
2900
CDL32-50-2
60
32
11
2900
CDL32-50
67
32
11
2900
CDL32-60-2
74
3
Vertical Multistage Centrifugal Water Pump>
Model NO.: TY15102903
Position of Pump Shaft: Vertical Pump
Pump Casing Combined: Horizontal Split Pumps
Mounting Height: Since Irrigation Centrifugal Pumps
Impeller: Open
Usage: Pump
Packaging: Neutral Packing and Wooden Package
Trademark: PUMTIP
Transport Packaging: Wooden Box
Specification: JB/T53058-93
Origin: China
Product Features:
1. Energy Efficient
2. Simple Structure, Easy Maintenance
3. Fine Appearance
4. Wide Range of Applications
Easy Demolition of Stainless Steel Vertical Multi-Stage Centrifugal Pump
When the seal is damaged and needs to be replaced after long-term operation, there is no need to remove the parts below the motor and pump body. Only the coupling needs to be removed for replacement, ensuring the concentricity of the motor shaft and pump shaft and the sealing performance of the pump body. Replacing mechanical components will not affect the overall lifespan of the product.
Product Applications:
1. Municipal Water Supply and Pressurization
2. Circulatory and Processing Systems in Industrial Settings
3. Environmentally Friendly Water Treatment and Penetration Analysis Systems
4. Urban Water Supply Construction
Technical Parameters:
1. Flow: 0.4–65 m³/h
2. Head: 6–230 m
3. Rotating Speed: 2900 r/min
4. Diameter: Dia 25–Dia 100 mm
5. Liquid Temperature Range: -30°C to +150°C
6. Working Pressure: Maximum 2.5 MPa
7. Medium: Suitable for liquid delivery, hot and cold clean water, softened water, as well as micro-alkaline, mineral water, and chloride solutions.
Prev Article
Vertical Multistage Pipeline Pump Dfl Type